Direct Connect

The MedGraphics Direct Connect preVent™ offers an accurate reliable solution for metabolic testing.

Key Benefits

  • Testing procedure is easier by eliminating the need to correct for continuous bias flow.
  • The Direct Connect preVent™ Pneumotach is the first metabolic assessment interface to allow direct
    measurement of a patient’s metabolism without
    compensating for, diverting or turning off bias flow.
  • This advance in metabolic assessment allows early and improved nutritional management of ventilator patients on a wide range of ventilators typically found in the ICU / CCU.
  • Optimizing nutritional states has been proven to decrease the number of ventilator days and, ultimately, to the length of stay in the ICU. This translates into improved patient outcomes and significant cost savings to the health care
    facility.

Key Features

  • Simple setup: The design saves time and eliminates hassles associated with more complex flow measuring devices.
  • Unsurpassed accuracy and reliability: Directly measures gas exchange without the need for correction factors, complicated connections or isolation valves.
  • Great efficiency: The Direct Connect preVent™ Pneumotach is the only completely disposable pneumotach on the market. Eliminate the concern over infection control and allow quick exchange between patients.
    “Snap-in & Snap-out”.

direct connect

Pictured above is the Direct Connect preVent Pneumotach in a ventilator circuit. It is a revolutionary flow device for unparalleled accuracy and infection control for metabolic assessment of ventilated patients.

 

Direct Connect

Specifications

The Measurement Principle

  • Patented, bi-directional, pitot tube pneumotach.
  • Output unaffected by condensation, turbulence, gas
    viscosity, temperature or position.

Resolution
2.4 ml/sec

Accuracy
±3% or 10 ml, whichever is greater

Size
Length: 8.5 cm (3.35")
O.D.: 1.75 cm (0.7")
Weight: 8.5 gm (0.3 oz)

Deadspace
Total: 14 ml

Software Requirements
BREEZESUITE


References

McArthur C, Donlin ME: Validation of a Breath by Breath Gas Exchange Monitor utilizing a Proximal Airway Flow Sensor during Mechanical Ventilation with Continuous Bias Flow, Respiratory Care 2002; 47:9 1087.

 

Direct Connect


Benotti PN, Bistrian B: Metabolic and nutritional aspects of weaning from mechanical ventilation, Critical Care Medicine 1989; 17:2 181-185.

Anderson CF, Loosbrock LM, Moxness KE: Nutrient Intake in the Critically Ill Patients: Too Many or Too Few Calories, Mayo Clinic Proceedings 1986; 61:853-858.

D'Attellis NP, Bursztein S, Askanazi J, Kvetan V: Tailoring nutritional support: What, when, and why, Journal of Critical Illness 1988; 3: 49-68.

Twomey PL, Patching SC: Cost Effectiveness of Nutritional Support, JPEN 1985; 9:3-10.